Soft-Close Toilet Seat Cover Damper – Electric Oil Damper, Made in Korea, 12V/24V price

Share This Article:

Oil damper / Electric damper
 
The oil damper is a device that uses hydraulic pressure to reduce movement and is mounted on a bidet cover. The electric damper is a damper that automatically opens or closes the bidet cover when the sensor detects movement. We, JK Corporation is introducing products to domestic and overseas markets in cooperation with Eransys, which is leading the damper market for Korean bidets.
※ Application: Bidet, Washing machine
 
Major Customers
  • Korea: Woongjin Coway, Novita, Izen, IS Dongseo, SK Magic, Nanutech, Daelim B&CO, Daelim trading, Chungho nais
  • Overseas: Samsung Electroncis, Toshiba, Sharp, Hitachi, Lixil
 
Oil damper
 
Coaxial Oil damper (BOD-Series)
  • Operation Angle: 0? ~ 120? [ Relief angle ±5° ]
  • Torque [Close]: Seat : 12~25 kgf-cm / Cover : 12~25 kgf-cm
  • Torque [Open]: < 12 kgf-cm
  • Closing Time [70?→0°/23°C]: 3.0~20.0 sec
  • Damping Direction: CW
  • Operating Temp.: 0 ~ 40°C 
  • Self Support Angle / Torque: 105° (Seat Only) / 15 kgf-cm ↑
  • Durability: > 50,000 cycles
  • Application: Bidet
 
Uniaxial Oil damper (BOD-X Series) - ?18
  • Operation Angle: 0° ~ 115° [ Relief angle ±2° ]
  • Torque [Close]: 8~20 kgf-cm
  • Torque [Open]: 8 kgf-cm
  • Closing Time [70°→0°/23°C]: 3.0~20.0 sec
  • Damping Direction: CW / CCW
  • Operating Temp.: 0 ~ 40°C 
  • Durability: > 50,000 cycles
  • Application: Bidet
 
Uniaxial Oil damper (BOD-2.0)- ?20
  • Operation Angle: 0° ~ 115° [ Relief angle ±3° ]
  • Torque [Close]: 15~25 kgf-cm
  • Torque [Open]: 12 kgf-cm
  • Closing Time [70°→0°/23°C]: 3.0~20.0 sec
  • Damping Direction: CW / CCW
  • Operating Temp.: 0 ~ 40°C 
  • Durability: > 50,000 cycles
  • Application: Bidet
 
Uniaxial Oil damper (BOD-2.2)- ?22
  • Operation Angle: 0° ~ 115° [ Relief angle ±5° ]
  • Torque [Close]: 15~30 kgf-cm
  • Torque [Open]: <14 kgf-cm
  • Closing Time [70°→0°/23°C]: 3.0~20.0 sec
  • Damping Direction: CW / CCW
  • Operating Temp.: 0 ~ 40°C 
  • Durability: > 50,000 cycles
  • Application: Bidet
 
Uniaxial Oil damper (WOD-1.2)- ?12
  • Open and close Operation Angle: 0° ~ 180° [ Relief angle ±10° ]
  • Operation Angle: 0° ~ 135° [ Relief angle ±10° ]
  • Torque [Close]: 7 kgf-cm
  • Torque [Open]: < 7 kgf-cm
  • Closing Time [70?→0°/23°C]: 4.0~15.0 sec
  • Damping Direction: CW 
  • Operating Temp.: 0 ~ 40°C 
  • Durability: 7,300 cycles
  • Application: Washing Machine
 
Electric damper
 
Electric damper (EDM-E1)
  • Rated Voltage: DC12V / DC24V
  • Rated Current: < 900mA / < 500mA
  • Open Torque: 20kgf-cm (Max) / 30kgf-cm (Max) / 40kgf-cm (Max) - Each Model
  • Open Time: 3.0sec (Max)
  • Rotated Direction (Open): CW / CCW - Each Model
  • Operation Angle: 0° (Relief angle : -5°) -120°C 
  • Sensor Type: Potentionmeter [ Left end: 3.1 / Right end: 6.9 ] -[4]-[5] terminal
  • Durability: > 50,000 cycles
  • Application: Bidet
 
Electric damper (EDM-B1)
  • Rated Voltage: DC12V / DC24V 
  • Rated Current: < 900mA / < 500mA
  • Open Torque: 20kgf-cm
  • Open Time: 3.0sec (Max)
  • Rotated Direction (Open): CW / CCW - Each Model
  • Operating Angle: 0° (Relief angle : -5° ) - 120°C 
  • Sensor Type: Potentionmeter [ Left end: 3.1kΩ / Right end: 6.9kΩ ] -[4]-[5] terminal 
  • Durability: > 50,000 cycles
  • Application: Bidet
 